[Free] 2017(Nov) EnsurePass Passguide IBM C9010-262 Dumps with VCE and PDF 51-60

EnsurePass
2017 Nov IBM Official New Released C9010-262
100% Free Download! 100% Pass Guaranteed!
http://www.EnsurePass.com/C9010-262.html

IBM Power Systems with POWER8 Enterprise Technical Sales Skills V2

Question No: 51 – (Topic 1)

A customer is comparing POWER8 and x86 solutions where availability of the Processor is a consideration.

What is a benefit of the POWER8 architecture?

  1. First Failure Data Capture

  2. Redundant registers

  3. Chip Kill

  4. Active Processor Mirroring

Answer: A

Topic 2, Exam Pool B

Question No: 52 – (Topic 2)

A customer is purchasing a 1-node E870 and requires the following: What can be added to the E870 to satisfy their requirement?

  1. Redundant SAS controllers and an EXP24S in mode 4.

  2. An EXP24S in mode 2 connected to the integrated SAS controller.

  3. A PCIe I/O Drawer, redundant SAS controllers, and an EXP24S in mode 1.

  4. Two PCIe I/O Drawers, redundant SAS controllers, and an EXP24S in mode 2.

Answer: D Explanation:

The EXP24S SFF Gen2-bay Drawer (#5887) is an expansion drawer with twenty-four 2.5- inch form-factor SAS bays.

With AIX, Linux, and VIOS, you can order the EXP24S with four sets of six bays, two sets of 12 bays, or one set of 24 bays (mode 4, 2, or 1).

It is recommended for SAS cabling ease that the EXP24S drawer be located in the same rack in which the PCIe adapter is located. Note, however, it is often a good availability practice to split a SAS adapter pair across two PCIe drawers/nodes for availability and that may make the SAS cabling ease recommendation difficult or impossible to implement.

Question No: 53 – (Topic 2)

A customer has a significant investment in open source software for performing in-memory analytics. This workload is currently deployed on Linux and recent x86 hardware.

What advantage would POWER8 Enterprise servers provide to this customer?

  1. Up to six times cache per core.

  2. Up to four times the cores per socket.

  3. Up to eight times the PCIe bandwidth.

  4. Up to ten times the ChipKill Correction rate.

Answer: B Explanation:

POWER8 includes support for simultaneous multithreading with eight cores per thread (SMT-8). By comparison, x86 systems are only capable of performing SMT-2. The ability to achieve four times the level of per-core performance allows organizations to do more with less, which in turn allows them to decrease their server footprint and potentially spend less on staffing, maintenance and troubleshooting.

References: http://www.thinkasg.com/blog/linux-on-ibm-power8-versus-intel-x86/

Question No: 54 – (Topic 2)

Which of the following is a feature exclusive to PowerVM Enterprise Edition?

  1. PowerSC

  2. PowerVP Performance Monitor

  3. HMC Virtual Appliance

  4. PowerVC

Answer: B Explanation:

PowerVP is part of the PowerVM Enterprise Edition, but not part of the PowerVM Standard Edition.

Note: PowerVP Performance Virtualization Monitoring: Allows for optimization of systems by mapping virtualized workloads to physical resources which highlights performance bottlenecks and shows a simple color coded performance health view.

References:

http://www-03.ibm.com/systems/power/software/virtualization/enterprise.html http://www-03.ibm.com/systems/power/software/virtualization/standard.html

Question No: 55 – (Topic 2)

Which of the following solutions satisfies a customer’s requirement for redundant FSPs in an E870 solution?

  1. Two E870 system nodes.

  2. One E870 system node and two System Control units.

  3. Two E870 system nodes and two System Control units.

  4. One E870 system node and one System Control unit.

Answer: D Explanation:

The system control unit provides redundant system master clock and redundant system master Flexible Service Processor (FSP) and support for the Operator Panel, the system VPD, and the base DVD. The system control unit provides clock signals to the system nodes with semi-flexible connectors. A system control unit is required for every E870 system.

References: IBM Power Systems E870 and E880, Technical Overview and Introduction (December 2014), page 2

Question No: 56 – (Topic 2)

A client with a single node E870 would like to attach two I/O expansion drawers to provide more PCI slots.

What is the maximum number of full height PCI slots available with this configuration?

  1. 32

  2. 30

  3. 24

  4. 26

Answer: C Explanation:

The 19-inch 4 EIA (4U) PCIe Gen3 I/O Expansion Drawer (#EMX0) and two PCIe FanOut Modules (#EMXF) provide 12 PCIe I/O full-length, full-height slots.

References: https://www- 01.ibm.com/common/ssi/ShowDoc.wss?docURL=/common/ssi/rep_ca/0/897/ENUS114- 160/index.htmlamp;request_locale=en

Question No: 57 – (Topic 2)

For budgeting purpose, a customer wants to set aside all the storage for a particular workload which will run on 12 LPARs in Power E870. The CIO is worried that allocating all the storage to each LPAR from the beginning can lead to lack of storage in long term.

How can Shared Storage Pools benefit this customer?

  1. Shared Storage Pools provide automatic data archiving tools that prevent overconsumption of the storage.

  2. When storing data on Shared Storage Pools, the data is automatically compressed to take less space.

  3. All the storage will be allocated to the VIO servers but can be given to LPARs as required.

  4. Shared Storage pools automatically move data in the background to where it is needed most.

Answer: C Explanation:

To create a shared storage pool, you group VIOS virtual servers that share physical volumes. A storage pool is created and shared by all VIOS virtual servers that are members of the shared storage pool

References: http://www.ibm.com/support/knowledgecenter/SSAV7B_6.3.7/com.ibm.director.power.help s.doc/fsd0_vim_c_learnmore_storage_pool.html

Question No: 58 – (Topic 2)

Which of the following is used to identify compatible HMC and system firmware updates for a given system?

  1. Fix Level Recommendation Tool (FLRT)

  2. Entitled Software Support (ESS)

  3. Passport Advantage

  4. IBM Prerequisite Site

Answer: A Explanation:

The Fix Level Recommendation Tool (FLRT) provides cross-product compatibility information and fix recommendations for IBM products. Use FLRT to plan upgrades of key components or to verify the current health of a system. Enter your current levels of firmware and software to receive a recommendation. When planning upgrades, enter the levels of firmware or software you want to use, so you can verify levels and compatibility across products before you upgrade.

References: https://www-304.ibm.com/support/customercare/flrt/

Question No: 59 – (Topic 2)

A customer has an E850 and wants to add a GPU to enhance their financial trading application.

What is required to program the accelerator?

  1. CUDA

  2. OpenCL

  3. QEMU

  4. OPAL

Answer: A Explanation:

C/C CUDA programming support for POWER8 was first introduced with CUDA Toolkit

5.5 for Ubuntu 14.10 ppc64le.

The toolkit comes with tools and libraries that allow development of CUDA applications on Power including:

* GPU-accelerated libraries – provides many libraries and APIs, as for example, cuBLAS, cuFFT, cuSPARSE, Thrust.

References: https://www.ibm.com/developerworks/community/blogs/fe313521-2e95-46f2- 817d-

44a4f27eba32/entry/how_to_develop_nvidia_cuda_applications_on_ibm_power8?lang=en

Question No: 60 – (Topic 2)

A customer is purchasing two new POWER8 servers: each connected to its own DS8880 at different sites. The customer wants high availability with the least amount of downtime.

Which solution satisfies the customer’s requirements?

  1. Combine PowerHA with DS8880 data replication capabilities for automated failover across the sites.

  2. Use the DS8880 data replication capabilities to replicate the data across the sites.Configure PowerVM Live Partition Mobility for application availability.

  3. Create dual VIO servers on each POWER8 and double the total number of adapters in each machine.

  4. Use the DS8880 data replication capabilities to perform automated node failover across the sites.

Answer: A Explanation:

With AIX and DS8000, AIX HyperSwap will deliver both a high availability and a disaster recovery solution in an MGM three-site solution. PowerHA, formerly known as High Availability Cluster Multiprocessing, will provide management for HyperSwap. CSM will manage initial multi-target MGM setup, failback after HyperSwap, and Site Swap to the disaster recovery site to deliver high availability and disaster recovery in the multi-target MGM PowerHA environment.

References: https://www-01.ibm.com/common/ssi/cgi- bin/ssialias?infotype=anamp;subtype=caamp;appname=gpateamamp;supplier=897amp;letternum=ENUS 116-072

100% Free Download!
Download Free Demo:C9010-262 Demo PDF
100% Pass Guaranteed!
Download 2017 EnsurePass C9010-262 Full Exam PDF and VCE

EnsurePass ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 EnsurePass IT Certification PDF and VCE