Question No: 71 – (Topic 2)

A customer with a Power 770 is planning a migration to an E870. The 770 has four 8Gb PCIe 2-port Fibre Channel Adapters with all storage going through the SAN. The customer wants to keep the same WWPNs, and avoid a SAN reconfiguration.

What procedure should be recommended?

  1. Rezone the SAN because the existing WWPNs cannot be reused.

  2. Order a PCIe Gen3 I/O Expansion Drawer and relocate the HBAs into the drawer.

  3. Move the HBAs from the 770 and install them into the E870 system node.

  4. Order new HBAs and modify the WWPNs in the ASMI.

Answer: C Explanation:

Power 770 has six PCIe Gen2 integraded adapter slots per building block, with a system maximum of 24.

Power E870 has eight PCIe Gen2 integraded adapter slots per building block, with a system maximum of 16.

Note:

A World Wide Port Name, WWPN, or WWpN, is a World Wide Name assigned to a port in a Fibre Channel fabric. Used on storage area networks, it performs a function equivalent to the MAC address in Ethernet protocol, as it is supposed to be a unique identifier in the network.

A worldwide port name (WWPN) is a unique 64-bit identifier that is assigned to a fibre channel node port, called an N_port. The storage area network (SAN) administrator assigns storage to a WWPN.

An HBA (host bus adapter) is an integrated circuit adapter or circuit board that is designed to provide physical connectivity between a computer host and storage devices or a network.

References: Power Systems Capacity on Demand, page 47 https://public.dhe.ibm.com/systems/power/docs/hw/p8/p8ha2.pdf

Question No: 72 – (Topic 2)

Which kind of accelerator technology do S824L server products use?

  1. CAPI (consistency accelerator processor interface)

  2. GPU (graphics processing unit)

  3. FPGA (field programmable gate array)

  4. APU (accelerator Processing Unit)

Answer: A Explanation:

The CAPI can attach accelerators that have coherent shared memory access with the processors in the server and share full virtual address translation with these processors, using a standard PCIe Gen3 bus.

References:

Question No: 73 – (Topic 2)

A customer is considering a new POWER8 system. They want internal SSDs and HDDs to be virtualized to IBM i partitions using VIOS.

What should be considered when making this decision?

  1. The IBM i OS will use EasyTier to balance hot and cold data.

  2. The SSD and HDD can share the same EXP24S drawer.

  3. vSCSI must be used to virtualize the disk in VIOS.

  4. VIOS will use integrated IBM i capabilities to balance hot and cold data.

Answer: C Explanation:

IBM i Host amp; Client partitions

The creation of a Client partition leveraging iVirtualization consists of 2 main phases:

Ensurepass 2017 PDF and VCE

References: https://www.ibm.com/developerworks/community/forums/ajax/download/b392f5e7-cc45- 4261-a6cf-ee6acc3ba93e/d61b0887-7ab0-49b7-81c1-749e6931e7fe/iVirtualization –

IBM iHost and Client LPAR Easy Install Gui.pdf

Question No: 74 – (Topic 2)

Compared with the X86 technology, What is the difference of using CAPI to implement NoSQL memory database on POWER8?

  1. multi-node memory scalability

  2. have up to 80 threads in the drawer 4U server

  3. Shared memory and cache carry out dynamically adjust

  4. Easy Tier on FlashSystem storage

Answer: D

Question No: 75 – (Topic 2)

A customer would like to add a second HMC to an environment which consists of multiple POWER7 and POWER8 systems.

Which of the following is a requirement for both HMCs to be able to manage all the systems?

  1. Both HMCs must be on the same HMC VLAN.

  2. Each HMC must be on a dedicated HMC VLAN.

  3. All the POWER7 systems must be at the same firmware level.

  4. Both HMCs must be at the same version of HMC Code.

Answer: D Explanation:

HMC Version 8 can be used for POWER8, POWER7, and POWER6 based servers. HMC Version 7 can used for POWER7, POWER6 and POWER5 based servers.

References: https://www-304.ibm.com/support/customercare/sas/f/hmcl/home.html

Question No: 76 – (Topic 2)

Which of the following documents is designed to mitigate risk as part of the acquisition of a new E880?

  1. Power Estimator

  2. TDA Checklist

  3. Site Evaluation

  4. SSIC Listing

Answer: B Explanation:

After completing a TDA checklist, engage an IBM technical salesperson to review your technical delivery assessment to maximize customer satisfaction when selling and implementing IBM Software solutions.

References: https://www- 356.ibm.com/partnerworld/wps/servlet/ContentHandler/swg_com_sfw_technical-sales- support

Question No: 77 – (Topic 2)

A FlashSystem 840 attaches to a Power E870 via:

  1. 16Gb Fibre Channel adapter.

  2. 8Gb GX adapter.

  3. large write cache SAS adapter.

  4. Optical CXP converter adapter.

Answer: A Explanation:

The IBM FlashSystem 840 supports three different protocol interface cards:

References: Implementing IBM FlashSystem 840 (July 2015), page 26 http://www.redbooks.ibm.com/redbooks/pdfs/sg248189.pdf

Question No: 78 – (Topic 2)

A customer has an E870 that is currently using Elastic Capacity on Demand (CoD) for processors and memory. They have used all of their available processor enablement days.

What is the correct process to give them more enablement days?

  1. Process an MES to remove current enablements and reorder new enablements.

  2. Have the customer re-sign the CoD contracts.

  3. The customer must permanently activate the processors.

  4. Process MES orders to bill them for their usage.

Answer: A Explanation:

An Elastic CoD enablement code enables you to request temporary capacity on the server. You can make requests for temporary capacity over the life of the machine as long as your total days do not exceed the predefined limit. When the limit is reached, a new Elastic CoD enablement feature must be ordered and a new enablement code entered on your server. Each time a new enablement code is entered, it will reset the limit of processor days or memory days that can be requested as temporary capacity.

References: http://www.ibm.com/support/knowledgecenter/9119- MME/p8ha2/onoffcodconenable.htm

Question No: 79 – (Topic 2)

Which tool is recommended to assist in the design and deployment of partitions?

  1. System Planning Tool

  2. Eagle Study

  3. e-config

  4. Workload Estimator

Answer: A Explanation:

You can use the System Planning Tool (SPT) to design a managed system based on workload data from your current systems, based on new workloads that you want the managed system to support, based on sample systems that are provided with the utility, or

based on your own custom specifications. You can then use the system plan to order a system based on the specifications that the system plan contains. Also, you can use the HMC to deploy the system plan to configure an existing system when the target system meets the requirements for deployment.

References: Power Systems, System plans, page 1 https://www.ibm.com/support/knowledgecenter/POWER7/p7hc6/p7hc6.pdf

Question No: 80 – (Topic 2)

Customers want to rebuild AIX, IBMi and Linux logical partitions on a secondary physical server, so that it can use when the primary server fails.

Which of the following features provide this function?

  1. remote reboot

  2. Live Partition Mobility

  3. Inactive Partition Mobilitr

  4. Remote Recovery

Answer: B Explanation: Explanation

With Live Partition Mobility, users can migrate an AIX, Linux, or IBM i partition running on one POWER partition system to another POWER system without disrupting services. The migration transfers the entire system environment, including processor state, memory, attached virtual devices, and connected users. It provides continuous operating system and application availability during planned partition outages for repair of hardware and firmware faults.

Reference http://www- 01.ibm.com/common/ssi/ShowDoc.wss?docURL=/common/ssi/rep_ca/2/897/ENUS114- 062/index.htmlamp;amp;request_locale=en

100% Free Download!
Download Free Demo:C9010-262 Demo PDF
100% Pass Guaranteed!
Download 2017 EnsurePass C9010-262 Full Exam PDF and VCE

EnsurePass ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2017 EnsurePass IT Certification PDF and VCE